Plan · Permit · Prove · Walk away if it isn’t safe

Safe Isolation Starts Before You Touch the Board

The hardest part of safe isolation is not always the tester. Sometimes it is the customer asking, ‘How long will you be?’ The manager saying, ‘Can we keep that bit live?’The lost day’s pay if you walk away.

This site is a practical learning hub for planning, communicating and carrying out safe electrical isolation in the real world.

Explore the 10-point check. Learn the language. Practise the scenarios. Share the near misses.

Pressure mapthe worker, surrounded
State: baseline

Before the tools come out

The real job starts before the tools come out

Safe isolation does not begin when you arrive with a tester. It begins at the booking — in the permission you secure, the expectations you set, and the authority you carry onto site. By the time you reach the board, the most important decisions about whether the job can be done safely have usually already been made.

Get that groundwork right and the technical steps become almost mechanical. Get it wrong and every check happens under negotiation, with someone over your shoulder asking how long you’ll be.

Permission, expectations and authority are agreed before you arrive — not improvised at the board.

The pressure, named

Every technical step happens inside a human situation

Every technical step happens inside a human situation. Pressure changes decisions.

  • CustomerCan I just finish this meeting?
  • Site managerHow long will this take?
  • TenantThe freezer is full.
  • Business ownerWe can’t shut down card payments.
  • EngineerI’ve driven four hours to get here.

The 10-point check

Ten voltage checks, in order

Three-phase · dead testing sequence

  1. L1L2Line 1 to Line 2
  2. L1L3Line 1 to Line 3
  3. L2L3Line 2 to Line 3
  4. L1EarthLine 1 to Earth
  5. L2EarthLine 2 to Earth
  6. L3EarthLine 3 to Earth
  7. L1NeutralLine 1 to Neutral
  8. L2NeutralLine 2 to Neutral
  9. L3NeutralLine 3 to Neutral
  10. NeutralEarthNeutral to Earth

These ten tests sit inside the wider procedure — plan, permit, identify, isolate, lock off, prove, test, re-prove. The ten checks are not the whole job.


With guidance from

A learning resource, not a replacement for official guidance

IETHSEElectrical Safety FirstNAPITNICEICBS 7671Electricity at Work RegsGS38HSG85IET On-Site Guide

Forum · near misses

A refused isolation is a safety signal, not just a scheduling problem.

Submit a near miss

If the worker loses money every time they choose safety, the system is quietly rewarding risk.

The safest electrician is not the one who can work around every obstacle. It is the one who sees the pressure coming early enough to control it.